LOCTITE Stycast PC 18M, 3,86kg, 1gal can
Nr
IDH.500325
Product description:
LOCTITE STYCAST PC 18M is a solvent based one component urethane coating which may be cured at room temperature. This material retains its light color after long exposure to elements. Further information about the product: biuro@woronko-kleje.pl
Directions for use:
If material was stored below 23°C, it MUST be allowed to come to room temperature, in the sealed container, to avoid moisture contamination. Printed circuits or other objects to be coated should be cleaned in accordance with accepted industry practices. Isopropyl alcohol, or methyl ethyl ketone have been found satisfactory as cleaning agents. If activated flux residues are present, appropriate detergents may be needed to remove any residue.
Application:
1. Moisture may cause polymerization. Contents may solidify. If this occurs, warm to 49°C until clear and thoroughly mix beforeusing.
2. Apply by brush, dip or spray for a 1 to 2mil film.
Viscosity:
1. Viscosity may be reduced when desired with LOCTITE STYCAST AC 0305 thinner.
2. Other solvents such as methoxy propyl acetate, methyl ethyl ketone, xylene and toluene can be used alone or as a mixture depending on how coating will be applied and drying time desired.
3. Dilutions of 15 to 20 % will generally be sufficient for most applications.
Cleaning:
1. Uncured LOCTITE STYCAST PC 18M may be cleaned up with ketones or the solvents listed above.
Storage:
Store product in the unopened container in a dry location. Storage information may be indicated on the product container labeling. Optimal Storage : ≤23 °C. Material removed from containers may be contaminated during use. Do not return product to the original container. Henkel Corporation cannot assume responsibility for product which has been contaminated or stored under conditions other than those previously indicated.
Parameters:
Free TDI content, % : <1 NCO content, % : 4.0 Viscosity, Brookfield - RVF, 25 °C, mPa·s (cP):
- Spindle 2, speed 20 rpm : 350 Solids Content by weight, % : 50 Specific Gravity at 25ºC : 1.01 Shelf Life , Unopened @ 25°C (from date of manufacture), days : 548 Flash Point , ºC : 32
Full technical information can be found in technical data sheet
LOCTITE STYCAST PC 18M is a solvent based one component urethane coating which may be cured at room temperature. This material retains its light color after long exposure to elements. Further information about the product: biuro@woronko-kleje.pl
Directions for use:
If material was stored below 23°C, it MUST be allowed to come to room temperature, in the sealed container, to avoid moisture contamination. Printed circuits or other objects to be coated should be cleaned in accordance with accepted industry practices. Isopropyl alcohol, or methyl ethyl ketone have been found satisfactory as cleaning agents. If activated flux residues are present, appropriate detergents may be needed to remove any residue.
Application:
1. Moisture may cause polymerization. Contents may solidify. If this occurs, warm to 49°C until clear and thoroughly mix beforeusing.
2. Apply by brush, dip or spray for a 1 to 2mil film.
Viscosity:
1. Viscosity may be reduced when desired with LOCTITE STYCAST AC 0305 thinner.
2. Other solvents such as methoxy propyl acetate, methyl ethyl ketone, xylene and toluene can be used alone or as a mixture depending on how coating will be applied and drying time desired.
3. Dilutions of 15 to 20 % will generally be sufficient for most applications.
Cleaning:
1. Uncured LOCTITE STYCAST PC 18M may be cleaned up with ketones or the solvents listed above.
Storage:
Store product in the unopened container in a dry location. Storage information may be indicated on the product container labeling. Optimal Storage : ≤23 °C. Material removed from containers may be contaminated during use. Do not return product to the original container. Henkel Corporation cannot assume responsibility for product which has been contaminated or stored under conditions other than those previously indicated.
Parameters:
- Spindle 2, speed 20 rpm : 350
Full technical information can be found in technical data sheet