TEROSON EP 5065 - 200ml (klej epoksydowy do poszyć samochodowych o podwyższonej odporności na uderzenia)
Nr
IDH.2996614
Cena
247,47 PLN netto
/ szt.

Product description:
TEROSON® EP 5065 Impact Resistant Structural Bonder is an OEM approved, solvent free, two-component, high strength impact resistant adhesive, based on toughened epoxy resin. It is made for professionals to be mainly used in structural bonding of metals in car repair when crash behavior requirements are high. TEROSON® EP 5065 Impact Resistant Structural Bonder supports high crash impact absorption performance of a vehicle exposed to a collision, at high and low temperatures (-40 °C to 80 °C / -40 °F to 176 °F). This means the adhesive provides high crash safety for the driver and passengers in the aftermath of an accident, at various environment temperature conditions. Further information about the product: biuro@woronko-kleje.pl
The adhesive provides the following characteristics: High Impact resistance, high fatigue and stress durability for increased crashworthiness of the vehicle Excellent corrosion protection High crash safety standard to meet OEM production line requirement High crash performance on extreme temperatures (both low and high) Compatible with main types of metal used in automotive industry. Adheres to a wide range of materials (without primer) Can be used in combination with spot welding and riveting methods to meet OEM repair guidelines Typical application areas are engine mounts, strut tower, radiator support, A & B pillars, aprons, core supports, roof frame, sill, wheel arch, floors, and safety critical parts.
Directions for use:
During the storage and shipment, a crystallization of the resin may occur. By heating the adhesive @ 60°C (140°F) for about 60 minutes, this physical change is reversible. Afterwards, all properties will remain on the same level. It is recommended that the adhesive should be used at a minimum temperature of 15°C (59°F).
Pretreatment:
1. Bonding surfaces must be free of oil, grease, dust, or any other contaminant. Pretreat bonding surfaces with TEROSON® VR 10 and a lint-free cloth.
2. Remove old adhesive from existing body parts to make sure they are back to bare metal and free of any contamination.
3. Both bonding surfaces must be cleaned again to remove grinding dust. Pretreat bonding surfaces with TEROSON® VR 10. Allow the prepared surfaces to evaporate for approx. 5 minutes.
Application:
1. Unscrew coupling ring and remove cap from TEROSON® EP 5065 Impact Resistant Structural Bonder cartridge. Before attaching the static mixer to the cartridge, squeeze out a small amount of material until both adhesive components run equally. This is necessary to achieve a good mix of the two components.
2. Attach static mixer and tighten it. Insert the cartridge into the application dispenser. TEROSON® EP 5065 Impact Resistant Structural Bonder is processed with manual and pneumatic application tools (LOCTITE® HD14 Handheld Pneumatic Dual Cartridge Dispenser or LOCTITE® HD14 Handheld Manual Dual Cartridge Dispenser). Only use dispensers that are equipped with a piston rod.
3. When mixed, TEROSON® EP 5065 Impact Resistant Structural Bonder is very dark grey in color (almost black). Discard first 5cm (~2 inches) of adhesive.
4. Apply and spread TEROSON® EP 5065 Impact Resistant Structural Bonder with a spreader or brush. All bare metal areas should be covered with adhesive for corrosion protection. TEROSON® EP 5065 Impact Resistant Structural Bonder can be used on steel and aluminum car frame parts.
5. It may be necessary to change the static mixer if no material has been passed through it in over 30 minutes.
6. Join and fix components within the 60 minutes processing time. The processing time depends on the temperature. If spot welding is required, it must be carried out during this initial period. Do not subject bonded parts to stress before final cure. In order to avoid the bonded parts being displaced, it is recommended that they should always be fixed during the process of curing.
7. To ensure high crash safety performance, follow the manufacturer guidelines.
Curing:
1. Cure speeds may vary based on adhesive and substrate temperatures.
2. TEROSON® EP 5065 Impact Resistant Structural Bonder cures at room temperature (23°C, 50% RH)
3. During the curing phase, avoid movement or stress until the product is fully cured.
Cleaning:
1. It is important to clean up excess adhesive from the work area and application equipment before it hardens.
2. Remove excess adhesive immediately with spatula or cloth and TEROSON® VR 10. Cured adhesive can only be removed mechanically
Storage:
Store product in the unopened container in a dry location. Storage information may be indicated on the product container labeling. Optimal Storage: 15°C to 35°C (59°F to 95°F). Under certain conditions the product is frost sensitive. It may crystalize but it is reversible 60°C (140°F). Material removed from containers may be contaminated during use. Do not return product to the original container. Henkel cannotassume responsibility for product which has beencontaminated or stored under conditions other than thosepreviously indicated. If additional information is required, please contact your local Henkel representative.
Parameters:
Appearance (resin) : Black Appearance (hardener) : Grey / greyish Appearance (mixed) : Black Components Two components – requires mixing Viscosity : Low to medium Mix ratio, (by volume) - Resin : Hardener (2 : 1) Application temperature : 10 to 35°C (50 to 95°F) In service temperature : -40 to 90°C (-40 to 194°F) Short exposure (up to 1 hr) : 140°C (284°F) Final Cure, at 23°C, hours : 48 Final Cure, Accelerated Cure at 60°C, hours : 1 Final Cure, Accelerated Cure at 80°C, minutes : 30
Full information can be found on the technical sheet of the product.
TEROSON® EP 5065 Impact Resistant Structural Bonder is an OEM approved, solvent free, two-component, high strength impact resistant adhesive, based on toughened epoxy resin. It is made for professionals to be mainly used in structural bonding of metals in car repair when crash behavior requirements are high. TEROSON® EP 5065 Impact Resistant Structural Bonder supports high crash impact absorption performance of a vehicle exposed to a collision, at high and low temperatures (-40 °C to 80 °C / -40 °F to 176 °F). This means the adhesive provides high crash safety for the driver and passengers in the aftermath of an accident, at various environment temperature conditions. Further information about the product: biuro@woronko-kleje.pl
The adhesive provides the following characteristics:
Directions for use:
During the storage and shipment, a crystallization of the resin may occur. By heating the adhesive @ 60°C (140°F) for about 60 minutes, this physical change is reversible. Afterwards, all properties will remain on the same level. It is recommended that the adhesive should be used at a minimum temperature of 15°C (59°F).
Pretreatment:
1. Bonding surfaces must be free of oil, grease, dust, or any other contaminant. Pretreat bonding surfaces with TEROSON® VR 10 and a lint-free cloth.
2. Remove old adhesive from existing body parts to make sure they are back to bare metal and free of any contamination.
3. Both bonding surfaces must be cleaned again to remove grinding dust. Pretreat bonding surfaces with TEROSON® VR 10. Allow the prepared surfaces to evaporate for approx. 5 minutes.
Application:
1. Unscrew coupling ring and remove cap from TEROSON® EP 5065 Impact Resistant Structural Bonder cartridge. Before attaching the static mixer to the cartridge, squeeze out a small amount of material until both adhesive components run equally. This is necessary to achieve a good mix of the two components.
2. Attach static mixer and tighten it. Insert the cartridge into the application dispenser. TEROSON® EP 5065 Impact Resistant Structural Bonder is processed with manual and pneumatic application tools (LOCTITE® HD14 Handheld Pneumatic Dual Cartridge Dispenser or LOCTITE® HD14 Handheld Manual Dual Cartridge Dispenser). Only use dispensers that are equipped with a piston rod.
3. When mixed, TEROSON® EP 5065 Impact Resistant Structural Bonder is very dark grey in color (almost black). Discard first 5cm (~2 inches) of adhesive.
4. Apply and spread TEROSON® EP 5065 Impact Resistant Structural Bonder with a spreader or brush. All bare metal areas should be covered with adhesive for corrosion protection. TEROSON® EP 5065 Impact Resistant Structural Bonder can be used on steel and aluminum car frame parts.
5. It may be necessary to change the static mixer if no material has been passed through it in over 30 minutes.
6. Join and fix components within the 60 minutes processing time. The processing time depends on the temperature. If spot welding is required, it must be carried out during this initial period. Do not subject bonded parts to stress before final cure. In order to avoid the bonded parts being displaced, it is recommended that they should always be fixed during the process of curing.
7. To ensure high crash safety performance, follow the manufacturer guidelines.
Curing:
1. Cure speeds may vary based on adhesive and substrate temperatures.
2. TEROSON® EP 5065 Impact Resistant Structural Bonder cures at room temperature (23°C, 50% RH)
3. During the curing phase, avoid movement or stress until the product is fully cured.
Cleaning:
1. It is important to clean up excess adhesive from the work area and application equipment before it hardens.
2. Remove excess adhesive immediately with spatula or cloth and TEROSON® VR 10. Cured adhesive can only be removed mechanically
Storage:
Store product in the unopened container in a dry location. Storage information may be indicated on the product container labeling. Optimal Storage: 15°C to 35°C (59°F to 95°F). Under certain conditions the product is frost sensitive. It may crystalize but it is reversible 60°C (140°F). Material removed from containers may be contaminated during use. Do not return product to the original container. Henkel cannotassume responsibility for product which has beencontaminated or stored under conditions other than thosepreviously indicated. If additional information is required, please contact your local Henkel representative.
Parameters:
Full information can be found on the technical sheet of the product.